URD cable · Harris County / Greater Houston
We buy URD cable.
Subdivision loops and padmount transformers leave 15 kV and 25 kV cable behind. Most of it is aluminium with a concentric neutral, and a good deal of it never saw a trench.

Subdivision work across Harris County runs underground. The cable that feeds it is URD: stranded aluminium conductor, a concentric neutral wound over the insulation, rated 15 kV or 25 kV, and buried directly with no conduit around it. A developer builds the loop ahead of the houses, and when a phase is replatted or the lot count changes, the balance of the reel comes back to the yard.
Utilities hold their own surplus. Reels left from a reconductor job, spare cable bought for a storm response that never came, lengths returned by a contractor at the end of a subdivision contract. Some of it has never left the reel and some has been in a ditch and back out again. Both are bought, and the difference is settled at the jacket and the neutral.
How URD is built, at 15 kV and 25 kV
The construction is simple by medium voltage standards: a stranded aluminium conductor, a semi-conducting conductor shield, cross-linked polyethylene insulation, and a neutral made of copper wires laid concentrically over the insulation. Some cable has a jacket over that neutral and some does not. The jacketed version is the one that survives twenty years in Gulf Coast soil.
Sizes run from 2 AWG up to 1000 MCM, with 1/0 and 2/0 aluminium carrying most residential loops and larger sizes feeding three-phase runs and commercial pads. The neutral is either full size or reduced, and the jacket print tells you which. That ratio matters to a buyer because it changes how much copper is in a reel that is mostly aluminium.
Developer and utility surplus in Harris County
A subdivision is built on a forecast. The utility or the developer's contractor orders cable for the whole phase, installs the loops the houses need, and keeps the rest on a reel. When the next phase is redesigned, moved or sold, that remainder sits. Reels that were opened for one pull and never used again are the common case, not the exception.
Utility work produces the other half. A reconductor or a riser replacement leaves cut lengths with the neutral already trimmed. Storm stock that ages out of a rotation comes back as full reels. Contractors working under a utility contract return what they did not install, and the return is often a single reel with a tag and a hand-written footage note.
- Full reels from a phase that was replatted or sold
- Opened reels with one pull taken off the length
- Offcuts from padmount to meter pedestal loops
- Reels returned by a utility contractor at close-out
- Aged storm stock rotated out of a utility yard
- Unjacketed URD with the neutral exposed
Tags on URD reels are frequently the only record of footage. Photograph them before the reel is moved, because a reel that has been sitting outside for two summers will not have a readable tag afterwards.
What comes back from a padmount
A padmount transformer is fed from one side and feeds service laterals from the other, and every one of those runs is a cut length when the pad is relocated or a loop is reconfigured. Typical pieces run from thirty to eighty feet of 1/0 or 2/0 aluminium, cut at both ends, with the neutral and insulation exposed where the terminations were made.
Those pieces are workable cable. The questions are whether the insulation was damaged during removal, whether water sat in an open end, and whether the concentric neutral was cut back so far that the cable is no longer useful as a neutral-carrying run. A pad loop that was cut clean and coiled on site is worth reviewing; one dragged out by a backhoe usually is not.
Length matters less here than it does on a feeder. A forty foot pad loop in good condition is a normal piece to buy, because the next pad relocation will need exactly that kind of run. Coils that were rolled rather than folded keep their insulation round, and round insulation is what a splice kit is designed to sit on.
- Insulation free of gouges, ring cuts and backhoe damage
- Neutral intact, or cut back evenly rather than torn
- Ends sealed or taped, not open to the weather
- Jacket continuous where the cable is jacketed
- Coil diameter large enough that the cable was not kinked
Cable that was energised and cut out of service should be identified as such. It is bought, but it is graded as used rather than surplus.
Sending a URD lot
Give the voltage class, the conductor size, the neutral ratio if it is printed, the approximate footage and whether the cable is jacketed. A photograph of the jacket print and one of the reel tag answers most of it. For a dug-up lot, add a photograph of one cut end and say how the cable was removed.
Access is the other half. URD reels are heavy and usually stored at the back of a yard behind other material, so say what can reach them and whether a crane or a forklift is on site. If the reel has been sitting in standing water since the last storm, that is worth mentioning before anyone plans a route.
Related review paths
Questions sellers ask
Do you buy URD with the neutral cut back?
Yes. Neutral cut back at a termination is normal, and it is reviewed on how much of the neutral remains and whether it was cut cleanly. Cable with the neutral torn off at the insulation is graded differently.
Is 25 kV URD handled differently from 15 kV?
It is reviewed the same way, with more attention to insulation thickness and handling. The reels are often larger and the cable stiffer, so loading equipment matters more than it does for a 15 kV loop.
Can you take URD that was dug up?
Yes, with condition checked at the insulation and the neutral. Cable pulled from a trench can be perfectly good or badly damaged, and the difference is usually visible within a few feet of each end.
What length of URD makes a lot worth collecting?
A pad loop in the thirty to eighty foot range is a normal piece. Longer continuous lengths on a reel are the strongest lot. A handful of ten foot tails usually joins other material from the same yard.
Buying desk · Greater Houston
Got this cable in stock?
Tell us what is on the reel, where it sits and what condition it is in. A buyer reviews the lot, asks for photographs of the tag and the cut end, and comes back with a real answer — not a request to call a call centre.
- Cable type, size and voltage class
- Footage, reel count or weight, and condition
- City, and whether the site has loading equipment